The alert cleared at the exact moment the slot died
Monitor a Postgres replication slot by WAL-retention pressure and you inherit a sign flip at the terminal event: when Postgres invalidates the slot, pg_replication_slots reports wal_status='lost' and the lag columns go NULL — not huge. Coerce NULL to zero, compute 0% pressure, and your threshold evaluator concludes the condition cleared. The operator is told the pressure resolved at precisely the moment it became fatal.
Landed in sluice · 2026-07-16 · Postgres
What happened #
sluice's slot-health watcher pages on WAL-retention pressure: percent of max_slot_wal_keep_size retained for the slot, WARN at 70%, CRITICAL at 85%. The natural implementation reads the slot's lag from pg_replication_slots, computes a percentage, and compares against thresholds — and that implementation contains the trap twice over:
- When Postgres invalidates a slot (the WAL it needs got recycled past the cap), the row doesn't show an enormous lag. It shows
wal_status='lost'and NULL in the lag columns — the audit's live probe row wasactive=f | lost | NULL | NULL. - sluice's Postgres reporter mapped NULL lag to 0 bytes, and the threshold evaluator never read
WALStatusat all. NULL lag → 0% pressure → below every threshold →Cleared=true→ an INFO reading “condition cleared.”
So the observed sequence on the shipped binary was: page CRITICAL at 85%, keep paging as pressure climbs — then, at the exact tick the slot became irrecoverable, log “condition cleared” and go quiet. Terminal states in monitoring views often present as absent data rather than extreme data, and absent-means-clean defaults invert the alert exactly when it matters most.
The live differential #
The v0.99.258 cycle staged it on a throwaway postgres:16 with max_slot_wal_keep_size=1MB: stall the consumer realistically, burn WAL to ~92% of the cap (lag 969,120 bytes, identical on both binaries), take one in-condition retention pressure CRITICAL tick, then burn past the cap and CHECKPOINT so the slot invalidates live.
binary at the terminal event
--------- ------------------------------------------------------------
v0.99.257 next tick emits `postgres: slot-health condition cleared`
with wal_status=lost lag_bytes=0 — the false all-clear —
and NO lost page ever (lost=0, cleared=1)
v0.99.258 exactly ONE terminal ERROR: `slot INVALIDATED
(wal_status=lost) — terminal, re-snapshot required`;
ZERO clears; the pre-invalidation retention WARN intact
A staging detail worth recording: a plain fast burn on v0.99.257 (clean straight to lost, no sampled in-condition tick) emits nothing at all — reproducing the audit's exact false-clear shape needs the staged burn, one retention tick first.
The fix's shape — and its two siblings #
The repair is instructive beyond the one bug. First, dispatch on wal_status before any percentage math: lost pages CRITICAL exactly once and latches — never repeats, never clears — because the state is terminal by definition. But unreserved pages CRITICAL and stays clearable, because Postgres documents that an unreserved slot can recover; latching a recoverable state would re-create the inversion in the other direction (a stale alarm the operator learns to ignore). Truthful alerting cuts both ways.
Two siblings shipped in the same pass, both variations on “the net must be truthful at the terminal event”:
- A probe that fails silently is a disabled net. A revoked role or killed connection had the health probe logging DEBUG forever while the operator believed the alerting was live. Now five consecutive probe failures escalate to a WARN — “retention/invalidation alerts are blind until it recovers” — once per streak, with a recovery INFO. The cycle proved it live:
REVOKE SELECT ON pg_catalog.pg_replication_slots, CDC keeps applying while the probe is blind, the WARN fires at exactlyconsecutive_failures=5. - An edge-once latch must advance on delivery, not on decision. The schema-drift page's once-per-stall latch advanced before the notification was sent, so one transient sink error (a 502 at the stall moment) permanently swallowed the only page a persistent stall would ever get. The latch now advances only on successful delivery.
Plus one-tick hysteresis on threshold downgrades, so a catch-up hovering at the 85% boundary doesn't page every 30 seconds in both directions.
Reproducing it #
Throwaway container, ~5 minutes (this is the regression-cycle recipe):
docker run -d --name slotpg -e POSTGRES_PASSWORD=x -p 5460:5432 postgres:16 \
-c wal_level=logical -c max_slot_wal_keep_size=1MB
-- create a logical slot, attach a consumer (sluice sync or pg_recvlogical), then stall it
-- burn WAL past the cap and force recycling:
SELECT pg_switch_wal(); CHECKPOINT; -- repeat with junk writes until:
SELECT active, wal_status, safe_wal_size FROM pg_replication_slots;
-- f | lost | NULL <- the terminal row: status text, NULL numbers
Any monitor that computes pressure from the lag/safe_wal_size columns and treats NULL as zero will read that row as 0% — sluice ≤ v0.99.257 logged “condition cleared” on it; ≥ v0.99.258 pages terminal CRITICAL once. To see the false clear specifically, let the monitor sample one in-condition tick before the burn crosses the cap.
The transferable lesson #
When a monitored resource dies, its metrics don't spike — they vanish. Check the status column before the arithmetic, and treat absent data as “cannot assert health,” never as zero. Then audit the alert lifecycle at its edges: a terminal state should latch (one page, no clears, no repeats), a documented-recoverable state should not, a probe that can't see must say so, and a once-only notification must not mark itself sent until it was. Every one of those edges defaults to the quiet-and-wrong behavior if unexamined — and the quiet failure of an alerting net is indistinguishable from good news.
Primary sources #
- PostgreSQL documentation —
pg_replication_slots.wal_status(lost: “this slot can no longer be used”; the lag/safe_wal_sizecolumns go NULL) andmax_slot_wal_keep_size. - sluice v0.99.258 changelog — the lost/unreserved dispatch, probe-outage escalation, delivery-gated drift latch, and downgrade hysteresis; the 2026-07-15 audit findings MED-D0-9/10/11.
- sluice-testing session report v0.99.258 (F4/F4b) — the staged false-clear differential and the exactly-once terminal page, live on PG16.
- Companion field notes — postgres-slot-leaks and postgres-idle-slot-failover (how slots die; this note covers how their death reads as good news to your alerting).